Engineered Refrigeration Control

Liquid Line Filter Drier Manufacturer & Factories

Providing critical inline HVAC filtration, moisture capture, and system protection. Experience ISO-9001 certified OEM/ODM manufacturing capability direct from China's premier refrigeration accessories factory ecosystem.

Featured Filtration Products & Systems

China Molecular sieve liquid line filter drier & Solid Core Filter Drier

Molecular sieve liquid line filter drier & Solid Core Filter Drier

View Details
China Universal Copper Refrigeration Filter Drier

Universal Copper Refrigeration Filter Drier for Ice Maker Desiccant Dryer

View Details
Wholesale Universal Industrial Dryer Filter Cartridge

Universal Industrial Dryer Filter Cartridge for Ice Makers

View Details
Wholesale China Factory Suppliers Molecular Sieve Liquid Line Filter Drier

Molecular Sieve Liquid Line Filter Drier & Solid Core for Refrigeration Systems

View Details
China Brass Fittings for Refrigerator Freezer Parts

Brass Fittings for Refrigerator Freezer Parts - HVAC and Plumbing

View Details
China Suppliers Copper Accumulator Mufflers Filter Drier

Copper Accumulator, Mufflers, and Filter Drier for HVAC Parts

View Details
Wholesale Brass Brazing Rod for HVAC Systems

Brass Brazing Rod for HVAC Systems - High Strength & Conductivity

View Details
China Molecular sieve liquid line filter drier

Molecular Sieve Liquid Line Filter Drier & Solid Core Filter Drier

View Details

Liquid Line Filter Driers: The Core Guardian of Refrigeration Cycles

Within any vapor-compression refrigeration cycle, moisture, non-condensables, and debris pose critical threats. As a leading manufacturer of liquid line filter driers, Ningbo Taojun Refrigeration Equipment Co., Ltd. designs and manufactures products engineered to optimize system efficiency and prevent compressor breakdown.

🧪

3A Molecular Sieve Tech

Designed specifically to adsorb water molecules while ignoring refrigerant molecules. This guarantees a water adsorption rate of ≥20%, locking down critical system moisture limits before acids can form.

🛡️

Acid & Contaminant Neutralization

Active solid core formulations work to neutralize hydrochloric and hydrofluoric acids generated under thermal breakdown conditions. They also catch copper filings, flux residue, and oxidation scale.

Zero Resistance Flow

Engineered with structural mesh and porous cores to optimize cooling, reduce pressure drops, and boost refrigerant velocity, enhancing cycle COP.

Ningbo Taojun Factory View Production Process Filter Drier Core Assembly Welding Station Testing Lab
Who We Are

Ningbo Taojun Refrigeration Equipment Co., Ltd.

Located in Xiangshan, Ningbo, our company was founded in 1988 as the Xiangshan Refrigeration Accessories Factory of Zhejiang University. Over the past 30+ years, we have grown into a national high-tech enterprise specializing in the design, development, production, and sales of copper filter driers, check valves, air conditioning valves, and brass/copper components.

Our flagship "Lingshan" and "Taojun" brand products serve major home appliance enterprises like Haier, Midea, Gree, Whirlpool, Electrolux, and Xinfei. With ISO9001:2008, EU RoHS, and US UL certifications, we meet stringent global compliance standards.

  • R&D Core: 15 engineers in our R&D center, including PhDs and professors from the University of Science and Technology of China (USTC).
  • Global Delivery: Products exported to Europe, the Americas, Southeast Asia, the Middle East, and Africa.
  • German Technology: Precision forming and manufacturing equipment imported directly from Germany.

Localized Industrial & HVAC Applications

Taojun filter driers are designed to handle demanding industrial conditions, commercial refrigeration, and residential applications around the world.

1. Domestic Refrigerators & Freezers

Copper drying filters ranging from 10g to 20g are integrated into residential refrigeration loops to provide continuous moisture cleanup, supporting stable long-term operation for over 10 years.

2. Commercial Ice Makers

Specialized desiccant filter cartridges protect critical capillary lines and expansion valves in commercial ice machines from ice blockages, preventing system faults and costly service calls.

3. Automotive & Transport HVAC

Automotive air conditioning loops and refrigerated transport units face significant vibration and heat stress. Our solid-core filters provide reliable filtration under these high-demand road conditions.

38+
Years Industry Expertise
< 0.05%
Defect Rates (5D Quality Control)
50+
Countries Exported To
500 hrs
High & Low Temp Endurance Testing

China Supply Chain Resilience & Quality Control

01

Imported Material Inputs

To ensure high quality, we import our ITO film directly from Japan (for zero-shrinkage stability) and our adhesives directly from Europe. Protective films are designed to withstand temperatures of 80°C to 90°C.

02

Argon Arc Leakage Protection

Every copper filter shell is sealed using automated argon arc welding, followed by helium leak testing and high-pressure inspection to ensure zero leakage under operation up to 500 PSI.

03

Rigorous Reliability Testing

Finished filter driers undergo 500-hour environmental chamber testing (-35°C to 75°C), thermal shock testing (10°C to 90°C for 30 minutes), and moisture removal in high-temperature ovens before vacuum sealing.

Milestones & Infrastructure Evolution

1998 Factory Infrastructure

1998: Building Infrastructure

Establishing our specialized production base in Xiangshan.

2008 MES workshop

2008: MES Production Workshop

Transitioning to digital shop floor control for tracking processes.

2024 Modern R&D Center

2024: Next-Gen Integration

Optimizing smart filtration technology for eco-friendly refrigerants.

Global Trade Compliance

Your Verified OEM/ODM Partner

We hold official GB/T19001-2016 / ISO9001:2015 registration (No. 41325Q00065R0S), verified through the CNCA database. This system monitors our entire production line, tracking components from raw copper extrusion to final vacuum packaging.

We offer pre-sales technical consultation led by engineers with over 15 years of refrigeration experience. All standard lines are backed by our 1-year comprehensive replacement warranty and life-long technical support.

ISO 9001 Certificate

ISO 9001 Certificate

Registration Scope Certificate

Certification Scope

UL & RoHS Certificates

Safety Approvals

Integrated Workshop Active Product Line Testing Lab

Technological Roadmap & Future Outlook

As the global HVAC industry shifts toward low-GWP (Global Warming Potential) alternatives, filtration systems must evolve. Taojun is engineering next-generation liquid line filter driers to meet these changing environmental and mechanical standards.

Low-GWP & Natural Refrigerant Support

Developing compatibility solutions for HFO and natural refrigerants (such as R290 propane and CO2). This involves optimizing binder chemistries inside the solid core to prevent degradation under high operating temperatures and pressures.

Integrated Diagnostic Sensors

Researching smart filter-driers featuring embedded moisture and pressure-drop sensors. These units aim to provide real-time alerts when the desiccant reaches saturation or pressure drops exceed limits, helping to protect the compressor.

Sustainable Manufacturing

Adopting eco-friendly production methods, including lead-free brazing processes, 100% recyclable copper construction, and reduced-emission heat treatment ovens to lower the carbon footprint of our components.

Frequently Asked Questions (FAQ)

What is the difference between a 3A molecular sieve and standard activated alumina?

A 3A molecular sieve has a pore opening size of approximately 3 Angstroms. This allows it to adsorb water molecules (about 2.8 Å) while excluding refrigerant molecules, preventing chemical breakdown. Activated alumina is typically added to help adsorb organic acids and impurities, making a blended core suitable for systems that have experienced motor burnout.

How do I determine the correct size of liquid line filter drier for a system?

Sizing depends on the system's total refrigerant charge, the refrigerant type (e.g., R134a, R410A, R290), liquid line pipe sizing, and the expected flow rate. Standard residential systems typically use 10g to 25g copper filter driers, while commercial refrigeration and larger heat pumps require larger solid-core canisters to prevent excessive pressure drops.

When should a liquid line filter drier be replaced?

A filter drier should be replaced during any system service that opens the refrigerant loop. It should also be replaced if there is a noticeable temperature drop across the filter (indicating a restriction/clog) or if a moisture indicator shows high moisture levels.

Does Ningbo Taojun support custom OEM dimensions and connections?

Yes. As an OEM and ODM supplier, we manufacture filter driers in customized lengths, diameters, wall thicknesses, and connection sizes (soldered copper ODF or threaded SAE flare connections) to match your system specifications.

Refrigeration & Piping Component Catalog

Wholesale Defrost Timer & Thermostat Suppliers

Defrost Timer & Thermostat for Refrigeration Loop Protection

View Details
China Copper Alloy Capillary Coil Tube Suppliers

Copper Alloy Capillary Coil Tube for Air Conditioning and Evaporators

View Details
Wholesale Copper Fittings Suppliers for Refrigerators

High-Quality Copper Fittings for Refrigerators & AC Applications

View Details
Wholesale Molecular Sieve Liquid Line Filter Drier

Molecular Sieve Liquid Line Filter Drier | Solid Core Filter Drier

View Details
Wholesale Air Conditioning Copper Equal Tee Fittings

Air Conditioning Copper Equal Tee Fittings for Piping Connections

View Details
Wholesale Copper Split Service Valve

1/4" 3/8" 1/2" 5/8" Copper Split Service Valve & Gas Stop AC Parts

View Details
Wholesale Dual Gauge Valve for HVAC

Wholesale Dual Gauge Valve for HVAC/Refrigeration Systems

View Details
China 500 PSI Triple-Sealed Valve

500 PSI Triple-Sealed Valve for Industrial Refrigeration & HVAC

View Details
All Liquid Line Filter Drier Products